Addressable Control Panel
Description:
One loop & two loop addressable fire detection panel packed with features not usually associated with smaller systems, providing a high quality solution at exceptionally good value.
- Loop Capacity 235/477 intelligent
- 30/60 logical configurable zones and optional Fireman’s Control Panel
- Graphical LCD display
- Programmable from PC
- 30 Zone Indication and manual intervention panel
- Positive Alarm Sequence and Acknowledge Function
- Dirty Detector, Reporting and Test Function
- Built in RS485 mimic and repeater output (Maximum 10 repeaters)
- Optional GMC system and panel printer
- Advanced user friendly programming software including “Fuzzy Logic”
-
Addressable Heat Detector
Description:
This detector is extremely reliable for use in places that may have high dust levels or a smoky environment, making a normal smoke detector unsuitable.
- Fixed temperature and rate of rise heat detection
- It is aesthetically pleasing with a low profile, unobtrusive design that will complement modern building designs.
- Electronically addressed
- Twin LED for 360º vision
- With Remote indicator output
-
Addressable Manual Call Point
Description:
- Optional Back box for surface mount
- Re-settable (non-Breaking glass) with special key
- Easy 1st and 2nd Fix Installation
- Semi Flush or surface mount installation
- Pleasing Style design
- Protection Rating: IP55
- Operating Voltage: 24V DC
- Operating Current:
- Stand by Current: 0
- Alarm Current: 30mA
-
Addressable Smoke Detector
Description:
This unit is aesthetically pleasing with a low profile, unobtrusive design that will complement modern building designs. It has 8 bit processor with A/D converter and built in algorithm maps for false alarm rejections.
- Electronically addressed
- Twin LED for 360º vision
- Sensing chamber
-
Addressable Sounder
Description:
Providing two tones, Initiated by shorting External terminals, not affected by Loop power cut.
Polarity insensitive Signal Loop and Power Loop, with features of cable checking in case of power cut.
- Operation voltage: 24VDC Loop (16V-28V), 24VDC Power Supply
- Operation Current:
- Loop: Standby Current 1mA, Alarm current 5mA
- Power Supply: Standby Current 3mA, Alarm Current 50mA
- Sounder output: 94dB @ 1 Metre
- Polarized 2-core for loop and Polarized 2-core for loop
-
CAFS Trailer System
Burner Fire Control has been again selected to provide its 200 Gallon Compressed Air Foam Trailer Unit for emergency response for operations in the Arabic Gulf countries, Ghana, Africa. The CAFS 200 HD Trailer System provides self-contained and mobile capabilities to address potential surface hazards within the operations and surrounding areas. The Unit was shipped with Class A and B foam concentrate for mitigation of potential structural and hydrocarbon hazards.