SDS9056A
Product Features:
• Mountable semi—flush or on surfaces.
• Streamlined device addressing via portable coder.
• Single LED with 3600 viewing.
• Fast activation response,
• Equipped with a built—in microprocessor and sampling technology.
• Ensures high reliability and error detection.
• Low power consumption.
• Stable communication technique with high noise immunity.
• Comply with EN54-18, Certified by LPCB


Description:
The protector model P Deluge Valves is a quick opening hydraulically operated valve.
The valve may be actually manually (at the value location or remotely), hydraulically through the use of a wet pilot sprinkler, or electric type detector and/or electric control stations to actuate


Description:
Is Designed to be slim and lightweight, low power consumption, Low EMI and specially equipped with a customized propriety Hybrid IC and super bright white LED and longer life-span. Easy and Fast installation.


Description:
OS&Y gate valves operate by opening and closing via a gate, which lowers into or rises out of the valve.
Valve Standard: Conforms to AWWA C515/ BS5163
Working Pressure: 21 Bars/300PSI
Fusion Bonded Epoxy Coated Interior and Exterior RAL 3002
Flanged Ends: ANSI B16.1 Class 125/150/250, EN 1092-2 PN10/PN16
BS10 Table D/ Table E, Stainless Steel Stem


Description:
Fire safety and precaution is more than just installing fire extinguishers in your establishment. True fire preventive measure entails knowing which fire extinguisher is more suitable for your building. Having this particular knowledge maximizes the safety of everyone and can save multiple lives in the process. Dry Powder Extinguishers primarily contain the chemical monoammonium phosphate which is an extinguishing agent that can easily spread dousing over the flames in a split of time. Dry powder extinguishers are suitable for Class A, B, and C fires. Class A fires are those containing ordinary combustible materials such as cloth, wood, paper, and plastics. Class B fires are fires caused by flammable liquids such as grease, paint, and solvent. Class C fires are used are fires due to flammable gasses such as butane and methane. Dry powder extinguishers can be also used to extinguish fires due to live electrical wiring or equipment.
But apart from knowing what specific extinguisher should be used for a specific fire, it is important to know the external hazards as well. For example, it is not recommended to use dry powder extinguishers in enclosed spaces since it can be easily be inhaled by the people within the vicinity. Still confused? Do not worry PHLOX Security & Safety Equip. LLC is here and got you covered.
PHLOX Security & Safety Equip. LLC is a fire fighting and fire alarms supplier based in Sharjah, UAE. We also install fire-prevention alarms and systems and we have a wide range of products for different fire-preventive measures needed. We also provide our expertise and knowledge in recommending the best fire safety practices for your establishment that will guarantee everyone’s safety. We are one of UAE’s leading fire-prevention company and we attain this through supplying high-grade and quality products including dry powder extinguishers in the UAE.

Description:

Description:
Foam Fire Extinguishers are effective on class A & B fire.
AFFF is an extinguishing agent which seals the burning surface against ignition.
All Extinguishers are coated internally for optimal protection against rust and corrosion.
A foam extinguisher is good for general use, suitable for the majority of business premises.
The valve provided with safety release valve to release the excess pressure.


Description:
Landing Valves are suitable for installation on dry riser in building for firefighting protection. The landing valves are classified under low pressure and are suitable for use at nominal inlet pressure up to 15 Bar.
Disc facing rubber is replaceable type
Hand wheel is BLACK painted and body is RED


Description:
OS&Y gate valves operate by opening and closing via a gate, which lowers into or rises out of the valve.
Valve Standard: Conforms to AWWA C515/ BS5163
Working Pressure: 21 Bars/300PSI
Fusion Bonded Epoxy Coated Interior and Exterior RAL 3002
Flanged Ends: ANSI B16.1 Class 125/150/250, EN 1092-2 PN10/PN16
BS10 Table D/ Table E, Stainless Steel Stem

Description:
A check valve is probably in the discharge line of the pump.
It allows flow in one direction and automatically prevents back flow (reverse flow) when fluid in the line reverses direction.
Valve Standard: Conforms to AWWA C508, Clear waterway
Working Pressure: 21 Bars/300PSI
Fusion bonded epoxy coated RAL3002
Flanged Ends: ANSI B16.1 Class 125/150/250, EN 1092-2 PN10/PN16
BS10 Table D/ Table E, Stainless Steel Stem

PHLOX Security & Safety Equip. LLC
P.O. Box : 65433
Shed No. 4, Industrial Area 13
Sharjah, United Arab Emirates
PHLOX Security & Safety Equip L L C - Branch 01
Shop No. 1, Rashideya 3
Ajman, United Arab Emirates
We, PHLOX SECURITY & SAFETY EQUIP. LLC are glad to introduce ourselves as a supplier and we do installation of Fire Fighting and Fire Alarm materials and we are primarily located in Sharjah.
P.O. Box: 65433 ,Shed No. 4, Industrial Area 13 , Sharjah, United Arab Emirates