Single Door Hose Reel Cabinet
Description:
Single door cabinet used for manual and automatic hose reel, cabinets are made from mild steel with the sheet thickness of 1.2 mm. The outer edge of the hose reels is rolled over for safe handling and aesthetic appearance. The lock mechanism is either lock type, key type or turn handle. The cabinets are designed to accommodate fire hose reel manual Or Automatic.
Thickness of cabinets can be changed upon client’s request.
Available: Mild Steel and Stainless Steel
Description:
Fire safety and precaution is more than just installing fire extinguishers in your establishment. True fire preventive measure entails knowing which fire extinguisher is more suitable for your building. Having this particular knowledge maximizes the safety of everyone and can save multiple lives in the process. Dry Powder Extinguishers primarily contain the chemical monoammonium phosphate which is an extinguishing agent that can easily spread dousing over the flames in a split of time. Dry powder extinguishers are suitable for Class A, B, and C fires. Class A fires are those containing ordinary combustible materials such as cloth, wood, paper, and plastics. Class B fires are fires caused by flammable liquids such as grease, paint, and solvent. Class C fires are used are fires due to flammable gasses such as butane and methane. Dry powder extinguishers can be also used to extinguish fires due to live electrical wiring or equipment.
But apart from knowing what specific extinguisher should be used for a specific fire, it is important to know the external hazards as well. For example, it is not recommended to use dry powder extinguishers in enclosed spaces since it can be easily be inhaled by the people within the vicinity. Still confused? Do not worry PHLOX Security & Safety Equip. LLC is here and got you covered.
PHLOX Security & Safety Equip. LLC is a fire fighting and fire alarms supplier based in Sharjah, UAE. We also install fire-prevention alarms and systems and we have a wide range of products for different fire-preventive measures needed. We also provide our expertise and knowledge in recommending the best fire safety practices for your establishment that will guarantee everyone’s safety. We are one of UAE’s leading fire-prevention company and we attain this through supplying high-grade and quality products including dry powder extinguishers in the UAE.
Description:
The protector model P Deluge Valves is a quick opening hydraulically operated valve.
The valve may be actually manually (at the value location or remotely), hydraulically through the use of a wet pilot sprinkler, or electric type detector and/or electric control stations to actuate
Description:
A check valve is probably in the discharge line of the pump.
It allows flow in one direction and automatically prevents back flow (reverse flow) when fluid in the line reverses direction.
Valve Standard: Conforms to AWWA C508, Clear waterway
Working Pressure: 21 Bars/300PSI
Fusion bonded epoxy coated RAL3002
Flanged Ends: ANSI B16.1 Class 125/150/250, EN 1092-2 PN10/PN16
BS10 Table D/ Table E, Stainless Steel Stem
Description:
There are two commonly used fire extinguishers in the market. Part of fire safety and precaution is
knowing which fire extinguisher would be best for the possible fires that can occur in an establishment.
Carbon Dioxide extinguishers are primarily made of pressurized non-flammable carbon dioxide gas. CO2 extinguishers are easily recognizable since they have hard horns and does not have a pressure gauge. The extinguisher also contains a flexible hose attached to its hard horns. The pressure inside the cannister of the extinguisher is so high that dry ice may form when using the extinguisher. It also contains a valve with a safety release pressure to prevent any bursting of cylinders in situations of fires involving high temperatures. CO2 fire extinguishers should only be used for Class B fires, fires caused my flammable liquid, and Class C fires, fire that were triggered by faulty electrical wiring or circuitry. It is ideal to use in multi-risk fires. The main ingredient of the extinguisher, CO2, will extinguish the flames by displacing oxygen. The pressurized CO2 gas is also cold which also acts as a coolant to the burning fuels. It is important to note that CO2 extinguishers SHOULD NOT BE USED for Class A fires since the CO2 may not be enough to displace oxygen since materials that causes Class A fires can smolder and re-ignite. Laboratories, kitchens, mechanical rooms, rooms with flammable liquids are some establishments should be equipped with a CO2 extinguisher.
PHLOX Security & Safety Equip. LLC is a fire fighting and fire alarms supplier based in Sharjah, UAE. We are a leading expert in fire-safety systems and installation that would guarantee the safety of your establishment. We have a wide range of products for different fire-preventive measures needed, and we have the best and cost-effective CO2 extinguishers in UAE.
Description:
Fire safety should not be taken lightly. Placing very high fire-safety preventive measures is important since it keeps people safe from danger and harm. It can also minimize the cost from damage recovery and prevent future costs due to possible lawsuits. It is as important to place a good effort in knowing what particular safety measures are needed to prevent fire-related accidents.
Fire alarm cables is one case as well. Since these cables are used for fire alarms and fire-preventive measures, these cables should be able to function while there is an ongoing fire. Installing regular wires may cause larger fires or worse can lead to accidents since these wires are not specially made for the situation. There are a lot of considerations needed especially if you want to ensure the proper installation of your fire alarm system in your establishment. Luckily, PHLOX Security & Safety Equip. LLC is here to help you with your fire-related equipment needs.
PHLOX Security & Safety Equip. LLC is a fire fighting and fire alarms supplier based in Sharjah, UAE. We also install fire-prevention alarms and systems and we have a wide range of products for different fire-preventive measures needed, and part of our product offerings are specialized fire alarm cables that are UL listed in UAE. Particularly, we offer Soloarti Fire Alarm Cables that can come in two dimensions:1.5 mm x 2 core x 100 meter and 1mm x 2 core x 100 meter. This particular fire alarm cable can withstand to temperatures up to 250OC and are halogen free in its composition. More importantly, these multicore cables are fire resistant and can maintain circuit integrity in high temperatures. It prevents smokes and noxious fumes from interfering with the internal circuitry of sensitive equipment lessening the potential damage by acid forming gases.
Description:
Reliable and easy-to-operate central battery system constructed in accordance with the requirements.
The system monitors each output circuit individually and with the use of address modules – each luminaire.
Description:
There are certain situations that a smoke detector would not be enough in fire management and safety. In instances of smoldering fires, addressable smoke detectors would be the best choice. This smoke detector would be ideal for dense smokes of fires that were produced from the burning of soft furnishing, plastic, foam, or similar materials that easily smolders.
PHLOX Security & Safety Equip. LLC is a fire fighting and fire alarms supplier based in Sharjah, UAE. In terms of fire safety and prevention, we are a leading expert and we also install fire-prevention alarms and systems. We have a wide range of products for different fire-preventive measures needed, and we, specifically, offer the GST DC-9103E Conventional Rate of Rise and Fixed Temperature Heat Detector.
The GST DC-9103E is a new generation product of GST that works stably by being fixed with a highly reliable fire judging program. It is also built with a microprocessor enabling a compact design. When detecting fire signals, it can change its own current to transmit the proper signal to the fire alarm control panel or the location of the addressable zone monitor unit. This smoke detector will keep illuminating fire LED until it is reset by its own system ensuring that the signal would be well received by people within the vicinity of the hazard.
Other unique features of the model are its programmable classes enabling up to 3 classes of program. It also has a reed switch testing. Its design is sleek and aesthetically pleasing allowing a low-profile and unobtrusive design that can easily complement any modern building. It is also electronically addressed and it comes with a remote indicator as its output terminal. The LED contained in the smoke detector also allows 360O viewing and smoke detection. Lastly, the product complies with EN 54-5.
Description:
Description:
A check valve is probably in the discharge line of the pump.
It allows flow in one direction and automatically prevents back flow (reverse flow) when fluid in the line reverses direction.
Valve Standard: Conforms to AWWA C508, Clear waterway
Working Pressure: 21 Bars/300PSI
Fusion bonded epoxy coated RAL3002
Flanged Ends: ANSI B16.1 Class 125/150/250, EN 1092-2 PN10/PN16
BS10 Table D/ Table E, Stainless Steel Stem
Description:
This detector is extremely reliable for use in places that may have high dust levels or a smoky environment, making a normal smoke detector unsuitable.
PHLOX Security & Safety Equip. LLC
P.O. Box : 65433
Shed No. 4, Industrial Area 13
Sharjah, United Arab Emirates
PHLOX Security & Safety Equip L L C - Branch 01
Shop No. 1, Rashideya 3
Ajman, United Arab Emirates
We, PHLOX SECURITY & SAFETY EQUIP. LLC are glad to introduce ourselves as a supplier and we do installation of Fire Fighting and Fire Alarm materials and we are primarily located in Sharjah.
P.O. Box: 65433 ,Shed No. 4, Industrial Area 13 , Sharjah, United Arab Emirates